Smarter motor. Less power.
An efficient EC motor uses just 10 W on low speed and 16 W on high. Evolve-125 combines dependable extraction with low electrical demand.
125 mm / 5 inch · Standard
Airflow figures are maximum free-air ratings; installed airflow depends on the duct system.
125 mm / 5 inch · Standard
Low energy.High airflow.
High performance inline extractor fan.
Evolve-125 brings low energy extraction to 125 mm / 5 inch rigid duct systems, with two speeds and straightforward external switched control.
An efficient EC motor uses just 10 W on low speed and 16 W on high. Evolve-125 combines dependable extraction with low electrical demand.
Mixed-flow extraction delivers up to 275 m³/h (76 l/s maximum free-air rating) through 125 mm connections. Select the appropriate speed for your room and duct run.
Low speed delivers up to 228 m³/h at a rated 10 W. High speed raises maximum airflow to 275 m³/h at 16 W. Both speeds are included; selection is through installation wiring and suitable external switching.
Evolve-125 delivers up to 275 m³/h through 125 mm duct connections, with rated power of just 16 W on high speed. Select low speed for up to 228 m³/h at 10 W.
Rated power
Maximum airflow
*Manufacturer’s published ratings for the 125 mm motor. Maximum airflow is a free-air rating; installed airflow depends on the duct system. Power varies with the operating point.
Installed within a 125 mm duct run, Evolve-125 keeps the motor away from the room’s extract grille. Its compact body and mounting plate help it fit into a suitable ceiling void or accessible service space.
Evolve-125 has no built-in timer. Operate it through a suitable external switch or control. Low or high speed is selected through installation wiring and suitable external switching, following the supplied instructions.
Published motor performance for Evolve-125. Select the operating point using the required airflow and resistance of your installation.
| Performance | Low speed | High speed |
|---|---|---|
| Power input | 10 W | 16 W |
| Max. airflow | 228 m³/h | 275 m³/h |
| Max. airflow, l/s* | 63 l/s | 76 l/s |
| Sound pressure at 3 m | 26 dB(A) | 28 dB(A) |
| Current | 0.11 A | 0.13 A |
| Motor speed | 2,204 rpm | 2,562 rpm |
*l/s values are rounded as published in the manufacturer’s datasheet. Maximum airflow is a free-air value, not an installed extraction rate. Sound figures are published sound pressure levels at 3 m; room, ductwork and mounting affect the sound heard in use.
Use the fan curve and your duct system resistance to select the operating point. “Min” and “max” refer to the two included speeds.
| Dimension | Evolve-125 |
|---|---|
| Spigot ØD | 123 mm |
| Width B | 167 mm |
| Height H | 190 mm |
| Length L | 246 mm |
| Published base weight | 1.79 kg |
Use nominal 125 mm / 5 inch rigid ducting. Allow access around the fan for installation, wiring and removal of the motor section. Weight is the published base-size figure.
Straightforward answers about Evolve-125, the 125 mm Standard inline extractor fan.
Its EC motor uses electronic control to drive the fan efficiently, with published power inputs of 10 W on low speed and 16 W on high speed.
Use nominal 125 mm / 5 inch rigid ducting. The fan’s published spigot diameter is 123 mm. Match the duct system and fittings to this model and check the required airflow at the installed resistance.
No. Evolve-125 is the Standard control version with no built-in timer. Use a suitable external switch or control, following the supplied wiring instructions.
Yes. Low and high speed are both included. Your installer selects the appropriate wiring and external switching for the application. This model does not include a built-in speed selector, and generic dimmer-style speed controllers must not be used.
Yes, Evolve is designed for ducted extraction from bathrooms, shower rooms and other humid premises. Locate the fan in a suitable accessible position, within its permitted ambient temperature range, and have the electrical and ventilation installation designed and commissioned correctly. IPX4 is not, by itself, approval for every bathroom location.
Correctly sized extraction helps remove moisture-laden air at its source. Duct design, run time, replacement air and the building’s conditions all affect the result. With Standard control, the extraction run time is managed by the external switch or control; there is no built-in run-on timer.
Yes. The removable central motor and impeller section is designed for servicing without dismantling the connected air ducts. Keep access available and isolate the electrical supply before maintenance.
Evolve-125 by Blauberg
Explore the published airflow, power and sound ratings for this model.
| EAN Number | 5056194057813 |
|---|---|
| Impeller Type | Mixed Flow |
| Motor Type | EC |
| Electrical Supply | 1 Phase 220/250 50/60Hz |
| Size | 125mm |
| Maximum Airflow Rate (l/s) | 76 |
| Maximum Airflow Rate (m3/h) | 275 |
| Control Options | Standard |
| Duct Connection Size | 100mm Dia |
| Power (Watts) | 16w |